Zielsetzung

Environmental monitoring is one of the systems that decide about the product quality in the manufacture of sterile medicinal products. Both European and American GMP regulations place special focus on this topic.

The USP 1116, the new EU GMP Annex 1 and especially the FDA’s “Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing - Current Good Manufacturing Practice“ deal in detail with environmental monitoring.

However, many of the requirements laid down in these documents seem to be excessive for everyday practice on the one hand and leave great scope for interpretation on the other hand.

In practice, environmental monitoring programmes sometimes develop into time-consuming, cost- and personnel-intensive measures. Therefore, it is the aim of this Training Course to provide the participants with pragmatic recommendations for the creation and implementation of environmental monitoring programmes.

Within the framework of this Live Online Training, the participants are confronted with current hot topics, like:
  • Alert / action levels
  • Relationship to batch release
  • Locations and frequency
  • Identification of isolates
  • Sampling procedures
and get to know solutions for their own company practice.

Zielgruppe

This ECA Training Course is directed at staff from Production, Quality Assurance and Quality Control who is responsible for the planning and implementation of environmental monitoring programmes. It is also valuable for decision makers who have to deal with environmental monitoring data within the framework of product release.

Programm

Environmental Monitoring

Gesamtes Programm als PDF herunterladen

Environmental Monitoring
  • Why do we do it – what does it tell us?
Relevant Guidelines
  • The New EU-GMP Guide Annex 1
  • USP
  • FDA Aseptic Processing Guide
  • ISO 14644 and ISO13824
  • An overview about the most important guidances
Surface / Personnel Monitoring
  • Surface:
    • ­ How?
    • ­ Surface sampling techniques
    • ­ Limitations
    • ­ Validation?
  • Personnel:
    • When and how?
    • ­ Results and specifications
    • ­ How to deal with shedders/pathogen carriers.
Viable Air Monitoring
  • Regulatory Standards
  • Settle Plates
    • Validation
    • Drying Issues
    • Where to place them?
  • Active Air Sampling
    • Equipment options / comparison
    • Validation
    • Where to place them?
Clean Rooms – RABS – Isolator: Points to consider in Environmental Monitoring
  • Comparison of the technical concepts
  • Validation of microbiological media for the isolator
  • Selection of sampling points
  • Transfer of microbiological media
  • Interpretation of the results and handling of excursions
Non-viable (particulate) Air Monitoring
  • The grading of areas for manufacture of sterile medicinal products in the EU
  • How to claim classification of areas to current standards
  • How to ensure continuing compliance with the classification
  • Selection of sampling locations for qualification and routine
  • Particle monitoring, how and how often
  • Handling the data
Workshop / Case Study: How to Establish an Environmental Monitoring Programme / Use of FMEA to Determine Sample Points in Routine Monitoring
  • Identifying weaknesses in contamination control systems
  • Identifying locations which will provide “early warning” signals of loss of control
  • Preparing useful environmental monitoring SOPs
  • Keeping manageable records
Case Study: Trending of Environmental Monitoring Data
  • What is a trend?
  • How can I use electronic systems to track and trend EM data?
  • How to get meaningful information from trending
  • Alert and action level setting
  • Using trending as tool for pro-active environmental control measures
Microbiological Methods
  • Microbiological media, growth requirements
  • Identification of isolates
  • Validating your methods
  • Using rapid identification techniques
  • Recovery problems
  • Identification to the level of DNA, what value does it bring
Environmental Monitoring for Medical Devices
  • Environmental Monitoring requirements considering ISO and AAMI
    • ­Classified Cleanrooms
    • ­Controlled Environment
  • Real life example
  • What to do when excursions occur?
Environmental Monitoring for Non-Steriles
  • Why monitor non-sterile areas
  • Risk vs impact  
  • Overview of regulatory position  
  • Case study  
Deviation Management for Environmental Monitoring
  • Steps to be taken in case of excursions
  • When is an excursion a deviation?
  • Comprehensive root cause analysis
  • The nasty “re-occurrence”
  • Finding of appropriate actions
Workshop / Case Study: Interpretation of OOS Results
  • What is an OOS in environmental monitoring?
  • OOS in relation to trends
  • How to investigate
  • Follow-up and corrective actions
  • Consequences for batch release
Investigations / Documentation
  • The information content of “variable” data versus quantitative limits
  • Published and practical limits
  • The information content of qualitative data
  • Communicating with technical management and higher management

ECA-Member*: € 1690,-
Non ECA Member*: € 1890,-
EU/GMP Inspectorates*: € 945,-
APIC Member Discount*: € 1790,-

Alle Preise zzgl. MwSt. Wichtige Hinweise zur Umsatzsteuer.

* auch unkompliziert per Kreditkarte bezahlbar
American Express Visa Mastercard

icon
Weitere Termine vor Ort
Weitere Termine vor Ort nicht verfügbar
icon
Weitere Termine online
Weitere Termine online nicht verfügbar
icon
Aufzeichnung nicht verfügbar

Haben Sie noch Fragen?

Wir stehen Ihnen für weitere Auskünfte gerne zur Verfügung.
Tel.: +49 6221 84 44 0
E-Mail: info@concept-heidelberg.de

Frau mit Headset

Zurück

Teilnehmerstimmen - das sagen andere über unsere Seminare:

"Die Umsetzung mit Memberspot ist wirklich ausgezeichnet gelungen.
Es unterstützt die Wissensvermittlung und gewährleistet auch die richtige Durchführung des Kurses.”
Christian Wagener, WAGENER & CO. GmbH
GMP Basis-Einstiegsschulung (B 1) - Aufzeichnung Online Seminar, April 2024

Guter, breit gefächerter Überblick mit interessanten Verknüpfungen zur Praxis,
welche die Theorie super veranschaulicht.”
Marina Kicoranovic, Labor Hartmann GmbH
GMP/Basis-Einstiegsschulung (B 14), September 2023

Die Referenten waren sehr gut! Sie haben sehr klar gesprochen, nur sehr wenige englische Begriffe
verwendet (super) und waren sehr praxisbezogen.”
Astrid Gießler, Regierungspräsidium Karlsruhe
Live Online Seminar - Basiskurs Computervalidierung & Datenintegrität im GxP Umfeld (B 3), Juni 2023

Sehr guter Bezug zur Schulung für einen GMP-Anfänger. Habe mich sehr gut abgeholt gefühlt.”
Dr. Harald Werner, Infraserv GmbH & Co. Höchst KG
GMP-Basisschulung (B 1), Juni 2023

NEWSLETTER

Bleiben Sie informiert mit dem GMP Newsletter von Concept Heidelberg!

GMP Newsletter

Concept Heidelberg bietet verschieden GMP Newsletter die Sie auf Ihren Bedarf hin zusammenstellen können.

Hier können Sie sich kostenfrei registrieren.

Kontakt

Kontaktieren Sie uns

Haben Sie Fragen?

Concept Heidelberg GmbH
Rischerstraße 8
69123 Heidelberg

Tel. :+49622184440
Fax : +49 6221 84 44 84
E-Mail: info@concept-heidelberg.de

zum Kontaktformular