Zielsetzung

This course outlines the principles of planning, qualification and operation of cleanrooms & barrier systems and their associated HVAC systems in the GMP environment. Both the protection concepts and the premises for aseptic and non-sterile manufacturing will be addressed.

Hintergrund

Knowing the regulatory requirements on rooms and HVAC systems is an absolute prerequisite for all further steps like design, qualification and operation of clean rooms.

It is therefore essential to be aware of all restrictions and relations between material and personnel flows before starting with the building of clean rooms for pharmaceutical manufacturing. This is the starting point for the zone concepts and the required airlocks.

The clean room itself consists of floor, wall and ceiling systems suitable for the intended use.  Now, which systems are suitable for which clean zones or processes? How can an isolator be integrated in the concept?

The classification and qualification of the rooms have to be done after the construction. The formal requirements on qualification are the same for clean rooms dedicated to the manufacture of both sterile and non-sterile dosage forms. Only the contents to be examined and fulfilled are different.

Qualification – which serves the verification of the correct functioning of the production rooms – merges into the routine monitoring. Moreover, the systems in place for requalification, change control, deviation and maintenance ensure the GMP status to be kept.

Zielgruppe

This course is directed at staff in pharmaceutical engineering departments and production, involved in the planning, qualification or operation of clean rooms.
Engineering companies and GMP-planners are also the target group of this course.

Technical Details

To participate in an on demand training course or webinar, you do not need any software. The recordings are made available via a streaming server. In general, the recording is provided in MP4 format, which any PC (Microsoft Windows, Apple IOS) or tablet can easily display.
 
Timing and Duration:
When you register for the on demand Training course or webinar you can decide at what date you want to follow the training course online. For a 1-day training course you will have 2 days in which the stream is available (for 2-day training course 3 days and for a 3-day training course 4 days). Within in this timeframe you can start & stop the stream according to your needs.
In time before the scheduled date (your desired date) you will receive an e-mail from us with a link for direct participation as well as your log-in data.
 
Please be aware: The recording does not include the Q & A sessions.
 
Training Course Documentation and Certificate:
The presentations will be made available as PDF files via download shortly before the online training course. After the event, you will automatically receive your certificate of participation.

Programm

GMP Requirements for Clean Rooms and HVAC Systems in the Pharmaceutical Industry
  •  The EU GMP guide, Annex 1 and 15, ISO Norms and other GMP relevant guidelines
  •  Definition of cleanliness: particles and microbiological limits
  •  Comparison of EU und US requirements
  •  Requirements during planning, construction and operation
  •  Experiences from inspections
Zone Concepts
  •  Considering of the frame conditions: premises, number of floors, products, technologies
  •  Estimation of the required spaces (with regards to the equipment and production capacities)
  •  Requirements according to the different clean room zones
  •  How to develop material and personal flows: from process to layout
  •  Planning with the technical room book
  •  Specific pressures cascades and airlock requirements
  •  Examples for zone concepts for sterile and non-sterile manufacturing including highly potent compounds
HVAC Systems: from Planning to Commissioning
  •  Background for HVAC-Systems
  •  Design criteria
  •  GMP criteria and requirements for recovery time, air changes, air velocity, differential pressures, …
  •  Usage of flow visualisation tools
  •  The different concepts possible from 100% fresh air to recirculation
  •  Different production types and the influence on HVAC systems and their GMP relevance
  •  Filters
  •  Control strategies
  •  Energy aspects
  •  Requirements for the construction site
  •  Monitoring systems
GMP Requirements for Clean Room Walls, Ceilings and Floors
  •  Description of requirements coming from planning, ISO norms and GMP Guidelines
  • Overview of the different wall and ceiling systems used in the pharmaceutical industry
  • Components of wall systems: terminals, doors and Windows
  • The GMP-compliant clean room drain
  • Floors: Slip-resistance vs. GMP
  • Requirements for silicone joints (and coves)
  • Assignment of the different systems to the different clean room classes – which walls, ceilings and floors are appropriate/allowed for which cleanliness class?
  • Specifying the intended quality: the URS
  • How to determine the specified quality of walls, ceilings and floors
Barrier Systems
  • Definition of Isolator & RABS Systems
  • Pros & Cons of the different Systems
  • Prerequisites for the usage of isolator/RABS
  • Technical implementation of a barrier system
Particle Testing and the ISO 14644
  •  Leak testing of filters
  •  Measuring over and under pressure
  •  Determination of the number of air changes
  •  Measurement of the recovery time
  •  Particle measurement and classification of the room
  •  Requirements for particle counters
  •  Number of measuring points and volumes according to ISO
  •  Air flow study, smoke study (UDF)
  •  Documentation of results
Qualification of Clean Room & HVAC System
  •  Definitions: classification, qualification, requalification, monitoring and recurring tests
  •  Organisation of the qualification of rooms and HVAC systems
  •  Usage and example of a risk analysis
  •  Steps taken in URS, DQ, IQ, OQ, and PQ
  •  Tests in the different qualification stages
  •  Typical problems in clean room and HVAC systems qualification
  •  Periodic requalification – which tests are really necessary?
Operation of Clean Rooms / Barrier Systems
  •  Recurring particle measurements
  •  Routine microbiological monitoring
  •  Tests for isolators
  •  What to do for maintenance?
  •  Cleaning
  •  Requalification
  •  Trending of data, evaluation, the PQR
Recording from 23/24 May 2023
Duration of Recording: approx. 10 h 15 min

ECA-Member*: € 1490,-
Regular Fee*: € 1690,-
EU/GMP Inspectorates*: € 845,-
APIC Member Discount*: € 1590,-

Alle Preise zzgl. MwSt. Wichtige Hinweise zur Umsatzsteuer.

* auch unkompliziert per Kreditkarte bezahlbar
American Express Visa Mastercard

icon
Weitere Termine vor Ort
Weitere Termine vor Ort nicht verfügbar
icon
Weitere Termine online
Weitere Termine online nicht verfügbar

Haben Sie noch Fragen?

Wir stehen Ihnen für weitere Auskünfte gerne zur Verfügung.
Tel.: +49 6221 84 44 0
E-Mail: info@concept-heidelberg.de

Frau mit Headset

Zurück

Teilnehmerstimmen - das sagen andere über unsere Seminare:

Guter, breit gefächerter Überblick mit interessanten Verknüpfungen zur Praxis,
welche die Theorie super veranschaulicht.”
Marina Kicoranovic, Labor Hartmann GmbH
GMP/Basis-Einstiegsschulung (B 14), September 2023

Die Referenten waren sehr gut! Sie haben sehr klar gesprochen, nur sehr wenige englische Begriffe
verwendet (super) und waren sehr praxisbezogen.”
Astrid Gießler, Regierungspräsidium Karlsruhe
Live Online Seminar - Basiskurs Computervalidierung & Datenintegrität im GxP Umfeld (B 3), Juni 2023

Sehr guter Bezug zur Schulung für einen GMP-Anfänger. Habe mich sehr gut abgeholt gefühlt.”
Dr. Harald Werner, Infraserv GmbH & Co. Höchst KG
GMP-Basisschulung (B 1), Juni 2023

NEWSLETTER

Bleiben Sie informiert mit dem GMP Newsletter von Concept Heidelberg!

GMP Newsletter

Concept Heidelberg bietet verschieden GMP Newsletter die Sie auf Ihren Bedarf hin zusammenstellen können.

Hier können Sie sich kostenfrei registrieren.

Kontakt

Kontaktieren Sie uns

Haben Sie Fragen?

Concept Heidelberg GmbH
Rischerstraße 8
69123 Heidelberg

Tel. :+49622184440
Fax : +49 6221 84 44 84
E-Mail: info@concept-heidelberg.de

zum Kontaktformular